Spesifikasi dan Kualifikasi Gas di Central Processing Plant FTK PT.Pertamina EP Asset 4 Untuk Memenuhi Kebutuhan PLTU Tambak Lorok

Anas Puji Santoso, Furqon Tri Kurniawan

Abstract


The gas produced from wells in the Milan block has not met the gas specification and qualification standards that has been approved with the Tambak Lorok PLTU as consumers. Therefore, gas enters the FTK Central Processing Plant (CPP) to be purified to conform to the gas sales contract. After releasing between gas and liquid in Gas Separation Unit (GSU), the gas entering the Gas Acid Removal Unit (AGRU) to remove impurities and make the gas product into a sweet gas using a solution of Methyl Diethanolamine (MDEA). Then, the gas product enters the Dehydration Unit (DHU) to reduce the water content that is still contained in the gas product. In this process use the Triethylene Glycol (TEG) solution. After that the gas lead to the metering system, and the sample is also taken to calculate the Gross Heating Value (GHV) of the product gas. Related to the results, it can be stated that the FTK CPP gas product is still in accordance with the gas sales contract

Keywords


Gas Sweetening, MDEA, TEG, GHV.

References


Azubulke Achara, Michael Osuagwu. Improving gas dehydration using pre-inhibited glycol. The Shell Nigeria Exploration and Production Company. Ltd. SPE. 189114-MS. 2017.

Campbell J.M. Gas Conditioning and Processing, Vol2, 8th Edition. Oklahoma: Campbell Petroleum Series. 1998.

Fikar Cita, Tutuka Ariadji. Studi sensitivitas konsentrasi larutan methyldiethanolamine untuk proses penghilangan gas pengotor hidrogen sulfia dan pengolahan libah sulfur pada lapangan gas X. Institiut Teknologi Bandung. 2013.

Gironi F., Maschietti M., Piemonte V. TEG regeneration in natural gas dehydration plants: a study in the cold finger process. Universita degli Studi di Roma. Italy. 2007.

Maddox R.N. Gas and Liquid Sweetening. Campbell Petroleum Series. 1977.

Faisol Haq, Bambang L., Widjiantoro, Dhany Arifianto. Optimasi Penyerapan H2S terhadap perubahan suhu ambient dalam amine contactor dengan metode pemrograman non linear pada industi pengolahan gas alam di gresik. Institut Teknlogi Sepuluh November. 2012.

Ibeh S. U., Chibueze S. E., Abonyi C. L. An investigation of dehydration inefficiencies and associated design challenges in a gas dehydration unit-A case study of X gas plant. SPE 2016. 18413-MS. 2016.

Trian Drehe, Courtney Hocking, Michale Cavill, Adam Geard. Increasing sales gas output from glycol dehydration plants. Process Group Pty, Ltd. SPE 2014. 171415-MS. 2014.


Refbacks