Production Data Analysis and Sonolog for Determining Artificial Lift Design and Well Characteristic
Abstract
Tarakan Field, North Kalimantan is a part of PT. Pertamina EP Asset 5. The Tarakan Field has 5 structures in the form of Pamusian, Juata, Sesanip, Mangatal, and Sembakung. The Tarakan Field has 57 production wells and 6 injection wells. The wells at Tarakan field are produced with artificial lifts in the form of Sucker Rod Pump (SRP) totaling 25, Hydraulic Pumping Unit (HPU) totaling 11, Electric Submersible Pump (ESP) totaling 19 and Progressive Cavity Pump (PCP) totaling 2. The determination of artificial lifts is carried out by the design of well characteristics and production history. The design at Tarakan Field was carried out with an artificial lift in the form of ESP (Electric Submersible Pump). ESP is used according to reservoir and formation characteristics in Tarakan Field.
Water Control Diagnostic Plot is a method used to analyze the effect of control on produced water. Water Control Diagnostic plot is plot between WOR and WOR derivative vs time. The plot was carried out on a log-log scale. The plot on the Water Control Diagnostic Plot is then analyzed against the graph created by the KS Chan. So from the analyzed plot, it is found whether or not there is a problem in the well at Tarakan Field. The results of the graph analysis on the well at Tarakan Field on the chart show that the field does not indicate a problem.
Keywords: chan plot; design; esp; production
Water Control Diagnostic Plot is a method used to analyze the effect of control on produced water. Water Control Diagnostic plot is plot between WOR and WOR derivative vs time. The plot was carried out on a log-log scale. The plot on the Water Control Diagnostic Plot is then analyzed against the graph created by the KS Chan. So from the analyzed plot, it is found whether or not there is a problem in the well at Tarakan Field. The results of the graph analysis on the well at Tarakan Field on the chart show that the field does not indicate a problem.
Keywords: chan plot; design; esp; production
Full Text:
PDFDOI: https://doi.org/10.31315/jpgt.v1i1.3321